How do you protect an outdoor tankless water heater in a freeze?

Updated November 12, 2026 · By The HomeMemory team

The short answer

Keep it powered. Rinnai, Navien, Noritz and Rheem all say the built-in freeze protection only works with electricity, and Rinnai and Navien also want the gas on. It protects the heater, not the pipes and valves outside it, so insulate and heat-trace those. If the power fails in a freeze, Rinnai, Navien and Rheem say to drain the unit.

What the built-in protection covers, by maker

MakerWhat its freeze protection covers
RinnaiOutdoor models down to -4°F (indoor models to -22°F), when sheltered from direct wind and supplied with both power and gas.
NoritzCurrent outdoor installs rated to -4°F (indoor to -30°F). The NC380 series is -4°F either way. Needs electrical power. Some models have no freeze prevention.
RheemCeramic heaters protect its tankless gas units down to -30°F. The page does not say whether that is for indoor or outdoor units. Needs gas, water and power kept on.
NavienNo temperature published on the pages we read. Needs electricity and the gas valve open. Navien says not to install outdoors where it freezes.

This guide is for a gas tankless water heater mounted outside, in any place where winter nights drop below freezing. The figures below are what each maker publishes for its own units. Your model's manual is the final word.

What it does not protect

Every maker draws the same line. Rinnai's FAQ says the heater itself is protected but the plumbing and valves leading to it are not. Navien says the internal protection will not protect the external pipes, or the condensate drain line on a condensing model. Noritz's winter bulletin says its freeze prevention heaters will not stop plumbing outside the unit from freezing. Rheem says external piping and valves on an outdoor unit need their own protection.

Wind matters too. Rinnai's manual for its V53e outdoor model says any wind or air moving across the unit reduces its ability to protect itself. Noritz's cold-climate page gives its -4°F outdoor figure for conditions without wind.

Navien is the most cautious. It says that if your winters bring ice and snow, a tankless heater should not go outdoors or in an unheated garage, and its NPN-E outdoor series page says outdoor units should not be installed where there will be freezing temperatures.

Before winter: protect the pipes and valves

Rinnai says the pipes and valves feeding the heater must be heat traced and insulated. Rheem says to wrap insulation around both the hot and cold pipes and the valves, and to add heat tape or heating cable on the piping, plugged into a nearby 120V outlet.

Noritz lists insulation, heat tape, electric heaters, drain-down solenoids and pipe covers for the plumbing outside the unit, and names fiberglass or polyethylene insulation. Navien says to insulate the water pipes connected to the heater and to fit a pipe cover over the gas, water and power connections.

Noritz adds a caution that applies to all of this: heat tape only works when there is power, the same as the heater's own protection.

When a freeze is forecast

For normal freeze protection, the makers say to keep the power on, and those that mention gas say to keep it on. Navien says to keep the power and gas valves on, that the power switch and cord must stay on and connected, and that closing the gas valve limits its freeze protection. Rheem says to keep the gas and water connected and the electric power on. Noritz says not to unplug the unit or cut its power.

Plan for an outage. Navien suggests a battery backup or generator when freezing weather is predicted. Noritz says a battery backup runs freeze prevention for about 20 minutes to an hour, depending on its size, and that outages of hours or days call for a generator, which can also keep heat tape running. Noritz asks that backup power have a pure sine wave output.

Keeping water moving is a separate method, and the makers set it up differently. Navien says a pencil-width stream from a hot tap can prevent internal freezing. Noritz says to run 0.1 to 0.2 gallons per minute overnight through the hot side of the furthest fixture, with the gas to the heater off. Rinnai's V53e manual describes a flow of about 0.1 gallons per minute, a stream about 0.2 inches thick, with the heater turned off and the gas supply valve closed, for when the cold exceeds what the heater can handle or the power is lost. Rheem suggests leaving a hot faucet slightly open and putting any recirculation pump on a timer.

So the gas advice depends on the situation. With power on and the built-in protection working, Rinnai and Navien want the gas on. For the running-water method, Rinnai's manual and Noritz have the gas to the heater off.

If the power goes out: drain it

Rinnai's V53e manual says that if the power fails below freezing, the heater should be drained of all water, and that the condensate trap and drain line should be drained as well. Navien says the internal protection fails without electricity and you must drain the unit right away or have a battery backup. Rheem says to drain the unit completely if an outage is expected in freezing conditions.

The steps below are Rinnai's manual draining procedure for the V53e outdoor model (REU-VAM1620W-US) only. If you own another model, use the draining steps in your own manual. Rinnai warns that the water stays hot after the heater is turned off, and to wait until it cools before draining to avoid burns.

  1. 01Shut off the cold water supply and the gas supply.
  2. 02Turn off the temperature controller.
  3. 03Disconnect the power to the water heater.
  4. 04Set a container underneath to catch the water. Take the drain caps off both isolation valves and open both valves above the caps (the blue and red handles), or remove the hot water drain plug instead.
  5. 05Remove the water filter to drain the cold water.

Other makers point you to their own manuals rather than publishing steps on these pages. Noritz says to isolate the heater using the valves on the hot and cold lines, and that this depends on shut-off valves having been installed under the unit. Navien says draining instructions are in its user's manual. To refill a V53e, Rinnai says to confirm the gas is off and taps are closed, refit the filter and drain caps and close both isolation valves, open the cold supply and run a tap until water flows, restore power, and only then, with the controller off, turn the gas back on.

Automatic drain-down kits

Noritz says that where power outages are frequent, a battery backup or drain-down solenoids should be used. Rinnai strongly recommends an optional drain-down system on units installed outside in cold climates, and says it drains the unit if there is a power or gas outage or a component failure. Its V53e manual lists the drain-down solenoid valves as kit 104000059, and says the condensate trap drain plug and water drain plug still have to be opened by hand.

Noritz says solenoid valves self-drain internal water when the power shuts off, and its winter bulletin describes them as draining the system partially.

If it has already frozen

Rinnai's V53e manual says not to operate the heater if it or its outside piping is frozen. It says to close the gas and water valves, turn off the power, wait for the water to thaw (check by opening the water supply valve), then check the heater and pipes for leaks. Rheem's general advice for a frozen water heater is to turn off the gas or electrical supply right away and never to force a thaw with high heat or by restarting the system, and that a licensed professional should look at it if anything is damaged or it does not run normally after thawing.

Navien's steps differ. It says to turn the heater off with the power button on the front panel, close the gas valve, open the hot tap nearest the heater, and warm the heat exchangers with a hair dryer or portable electric heater, checking every few minutes for water at the open tap. Once water flows, check the heater and piping for leaks, and contact a licensed professional if it leaks or does not run properly.

Navien says to stop and call a licensed plumber or technician in four cases. First, if water drips from the bottom of the unit itself. Second, if you smell gas (sulfur or rotten eggs) while thawing: turn off the gas supply at once, leave the house and call a professional. Third, if error codes remain after a thaw and a hard reset. Fourth, if the frozen section is inside a wall or crawlspace you cannot safely reach, where Navien says not to risk open flames or makeshift heating tools.

For a leak, Rheem says to turn off the water and the gas or electrical supply to the unit and call a plumber. If a pipe has burst outside the heater, Rheem says to shut off the home's main water supply and call a plumber.

Check the warranty before you count on it. Rinnai's V53e manual, Navien's frozen heater page and Noritz's winter bulletin each say freeze damage is not covered. Rheem's winter weather tips page says that if a licensed professional finds the unit is not working because of freezing, that is not covered under its tankless gas warranty.

Why this one slips

Freeze protection asks nothing of you most of the year, so it is easy to forget it depends on a power cord, an open gas valve and pipe insulation that went on years ago. The night it matters is often the night the power goes out.

The drain steps live in a manual, the valve kit number lives with the installer, and the warranty terms live somewhere else again. That is the kind of thing a home should remember for you.

Common questions

Does a tankless water heater need gas for freeze protection?

For the built-in protection, Rinnai says its rating applies when the heater has both power and gas, Navien says closing the gas valve limits freeze protection, and Rheem says to keep the gas connected. Noritz describes its protection as electric heaters that need power. The running-water method is different: Noritz and Rinnai's V53e manual run it with the gas to the heater off.

How long will a battery backup keep freeze protection running?

Noritz says a battery backup runs freeze prevention for roughly 20 minutes to an hour, depending on the battery, and recommends a generator for outages of hours or days. Navien suggests a battery backup or generator when freezing weather is predicted.

Is freeze damage covered by the warranty?

Not by the makers we checked. Rinnai's V53e manual, Navien and Noritz each say freeze damage is not covered, and Rheem says a unit a licensed professional finds has stopped because of freezing is not covered under its tankless gas warranty.

Should I leave a hot tap running in a freeze?

It can help, as a backup. Navien describes a pencil-width stream of hot water, Noritz says 0.1 to 0.2 gallons per minute overnight with the gas to the heater off, and Rinnai's V53e manual describes about 0.1 gallons per minute with the heater off and its gas valve closed.

Sources

This guide is general information. Your owner’s manual is the authority for your model, and gas appliances should be serviced by someone qualified to work on them.